Iatrogenic pseudoaneurysm of the middle meningeal artery after external ventricular drain placement

J Neuroimaging. 2015 Jan-Feb;25(1):140-1. doi: 10.1111/jon.12080. Epub 2014 Feb 19.

Abstract

External ventricular drain (EVD) placement is often a routine but lifesaving neurosurgical procedure performed throughout the world. Misadventures involving the procedure are well documented throughout the literature. However, we present a unique case of middle meningeal artery pseudoaneurysm formation after EVD placement not before described and provide a review of the literature.

Keywords: EVD; Pseudoaneursym; hydrocephalus; middle meningeal artery.

Publication types

  • Case Reports

MeSH terms

  • Aneurysm, False / diagnostic imaging
  • Aneurysm, False / etiology*
  • Cerebrospinal Fluid Shunts / adverse effects*
  • Cerebrospinal Fluid Shunts / instrumentation
  • Humans
  • Iatrogenic Disease
  • Male
  • Meningeal Arteries / diagnostic imaging*
  • Middle Aged
  • Radiography
  • Treatment Outcome
  • Ventriculostomy / adverse effects*