To assess the benefits of medical image three-dimensional visualization system assisted pancreaticoduodenctomy for patients with hepatic artery variance

Int J Med Robot. 2014 Dec;10(4):410-7. doi: 10.1002/rcs.1590. Epub 2014 Apr 8.

Abstract

Background: Our main aim was to evaluate the value of medical image three-dimensional visualization system (MI-3DVS) in pancreaticoduodenctomy patients with hepatic artery variance.

Methods: 114 patients who had undergone pancreatoduodenectomy were retrospectively summarized and analyzed. Clinical data of 64-slice multidetector CT angiography (64-MDCTA) scanning was introduced into MI-3DVS for procedural segmentation, registration and 3-dimensional (3D) reconstruction. The findings were compared with those found during the operation and by postoperative digital subtraction angiography (DSA) of coeliac artery.

Results: The 3D model demonstrated the origination and bifurcations of blood vessels, and the relationships among neoplasms, organs and blood vessels efficiently. About (14/114 cases, 12.3%) had variant. The sensitivity, specificity and accuracy of MI-3DVS in variant hepatic artery diagnosis were 100%. It assisted in preoperative procedural planning that was consistent with intraoperative findings.

Conclusions: MI-3DVS can be applied for accurate diagnosis of hepatic artery variance. It also provides detailed preoperative guidance for individualized procedural planning.

Keywords: 3-dimensional reconstruction; diagnosis; hepatic artery variance; medical image; pancreaticoduodenectomy; treatment.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adult
  • Aged
  • Aged, 80 and over
  • Angiography, Digital Subtraction
  • Female
  • Hepatic Artery / diagnostic imaging*
  • Humans
  • Imaging, Three-Dimensional / methods*
  • Male
  • Middle Aged
  • Multidetector Computed Tomography
  • Pancreatic Neoplasms / surgery*
  • Pancreaticoduodenectomy / methods*
  • Retrospective Studies