Comparison of myelin water fraction from multiecho T2 decay curve and steady-state methods

Magn Reson Med. 2015 Jan;73(1):223-32. doi: 10.1002/mrm.25125. Epub 2014 Feb 11.

Abstract

Purpose: Myelin water fraction is conventionally measured from the T2 decay curve. Recently, a steady-state approach entitled multicomponent-driven equilibrium single pulse observation of T1 /T2 (mcDESPOT) was employed for myelin water fraction mapping. However, no direct comparison between the established multiecho T2 relaxation method and mcDESPOT has been performed.

Methods: Gradient and spin echo (GRASE) acquired T2 decay curve and mcDESPOT measurements were acquired from 10 healthy volunteers using a 3T MRI. We compared myelin water fraction, transmit radio frequency field (B1 ), and T2 's of intra- and extracellular water obtained from both methods.

Results: For all brain regions examined, myelin water fractions from mcDESPOT were significantly higher than those from multiecho GRASE. B1 maps were qualitatively similar between GRASE and mcDESPOT, but multicomponent T2 times were significantly different. To investigate the effect of exchange, mcDESPOT data were analyzed with and without exchange. When exchange was turned off, intra- and extracellular T2 times from mcDESPOT were roughly consistent with GRASE results; however, myelin water fractions derived from mcDESPOT were still significantly higher than those derived from GRASE.

Conclusion: Myelin water fraction values derived from mcDESPOT cannot be considered to be equivalent to those derived from T2 decay curve approaches.

Keywords: T2 relaxation; mcDESPOT; myelin water fraction; steady-state imaging.

Publication types

  • Comparative Study
  • Evaluation Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adult
  • Algorithms
  • Body Water / chemistry*
  • Brain Chemistry*
  • Echo-Planar Imaging / methods*
  • Female
  • Humans
  • Image Interpretation, Computer-Assisted / methods*
  • Male
  • Middle Aged
  • Molecular Imaging / methods
  • Myelin Sheath / chemistry*
  • Nerve Fibers, Myelinated / chemistry*
  • Reference Values
  • Reproducibility of Results
  • Sensitivity and Specificity
  • Tissue Distribution