Evaluation of the effectiveness of training on a machine with a variable-cam

Acta Bioeng Biomech. 2013;15(4):93-102.

Abstract

The aim of the study was to assess the effectiveness of the training of elbow flexors through the use of 2 machines, one of which was equipped with a disc plate of constant radius, the other one with a variable-cam having a radius adjustable to muscle strength. The experiment included 45 men divided into 3 equal groups: training group A (variable-cam), training group B (circle), and control group C. The training lasted for 8 weeks, 3 times a week. In order to control the effects, the values of peak torque and power of the flexor muscles of the elbow were isokinetically measured for the angular velocities of 30°/s and 60°/s. Also taken were anthropometric measurements of the arm and the creatine kinase (CK) activity in the blood plasma. As a result of the training, significant increases of biomechanical values were noted only in group A: power increased over 20%, the peak torque over 14%. After the training, significant increases of arm circumference in the relaxed position were noted in group A (17 mm), as well as in group B (11 mm). Also, some changes in CK activity were observed between Monday and Friday in a training week. On the basis of the experimental measurements, it may be ascertained that training elbow flexor muscles on a machine with a variable-cam is more efficient for increases in strength and power, as well as for some anthropometric parameters, than training on a machine with a disc plate.

Publication types

  • Evaluation Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Arm / physiology
  • Creatine Kinase / blood
  • Elbow Joint / physiology
  • Humans
  • Male
  • Muscle Contraction / physiology
  • Physiology / instrumentation*
  • Physiology / methods*
  • Task Performance and Analysis*
  • Torque
  • Young Adult

Substances

  • Creatine Kinase