Evaluating hydraulic and disinfection efficiencies of a full-scale ozone contactor using a RANS-based modeling framework

Water Res. 2014 Apr 1:52:155-67. doi: 10.1016/j.watres.2013.12.037. Epub 2014 Jan 8.

Abstract

The capability of predicting hydraulic and disinfection efficiencies of ozone disinfection contactors is essential for evaluating existing contactors and improving future designs. Previous attempts based on ideal and non-ideal models for the hydraulics and simplified mechanisms for chemical reaction modeling have resulted in low accuracy and are restricted to contactors with simple geometries. This manuscript develops a modeling framework for the ozonation process by combining computational fluid dynamics (CFD) with a kinetics-based reaction modeling for the first time. This computational framework has been applied to the full-scale ozone contactor operated by the City of Tampa Water Department. Flow fields, residence time distribution, ozone concentration distribution, and concentration-contact time (CT) distribution within the contactor have been predicted via the computational framework. The predictions of ozone and bromate concentrations at sample points agree well with physical experimental data measured in the contactor. The predicted CT values at the contactor outlet demonstrate that the disinfection performance of the ozone contactor operated by the City of Tampa Water Department is sufficient to meet regulation requirements. The impact of seasonal flow rate change on disinfection performance is found to be significant and deserves attention during the management and operation of a water treatment plant.

Keywords: Full-scale contactor; Modeling; Ozone disinfection; RANS.

MeSH terms

  • Bromates
  • Disinfection / methods*
  • Florida
  • Hydrodynamics
  • Kinetics
  • Models, Chemical
  • Models, Theoretical*
  • Ozone
  • Seasons
  • Water Purification / instrumentation
  • Water Purification / methods*

Substances

  • Bromates
  • Ozone