Objective: To establish a method to determine lead and Isotope Ratios in whole blood by inductively coupled plasma mass spectrometry (ICP-MS).

Methods: The whole blood samples was removed protein by 5% nitric acid , Online join thallium (Tl) as internal standard substance, used lyophilized bovine blood lead and cadmium standard material (GBW09139h and GBW09140h) for quality control of blood lead concentrations. Lead isotope standard substances (GBW04426) is used to determine the correction factor, lead isotope ratios will lead isotope standard reference material NIST SRM981 by icp-ms with samples for testing.

Results: Optimize the detection method, detection of blood lead and lead isotope, and the method of linear range r >0.9999, GBW09139h and GBW09140h test results are within the scope of quality control. NIST SRM981 isotope determination precision RSD<1%, NIST SRM981 test results and the certificate of value close to.

Conclusion: The method is simple and convenient data is reliable, can meet the total lead (pb) in blood and former isotope simultaneous determination.