A novel amperometric alcohol biosensor developed in a 3rd generation bioelectrode platform using peroxidase coupled ferrocene activated alcohol oxidase as biorecognition system

Biosens Bioelectron. 2014 May 15:55:120-6. doi: 10.1016/j.bios.2013.12.005. Epub 2013 Dec 10.

Abstract

Alcohol oxidase (AOx) with a two-fold increase in efficiency (Kcat/Km) was achieved by physical entrapment of the activator ferrocene in the protein matrix through a simple microwave based partial unfolding technique and was used to develop a 3rd generation biosensor for improved detection of alcohol in liquid samples. The ferrocene molecules were stably entrapped in the AOx protein matrix in a molar ratio of ~3:1 through electrostatic interaction with the Trp residues involved in the functional activity of the enzyme as demonstrated by advanced analytical techniques. The sensor was fabricated by immobilizing ferrocene entrapped alcohol oxidase (FcAOx) and sol-gel chitosan film coated horseradish peroxidase (HRP) on a multi-walled carbon nanotube (MWCNT) modified glassy carbon electrode through layer-by-layer technique. The bioelectrode reactions involved the formation of H2O2 by FcAOx biocatalysis of substrate alcohol followed by HRP-catalyzed reduction of the liberated H2O2 through MWCNT supported direct electron transfer mechanism. The amperometric biosensor exhibited a linear response to alcohol in the range of 5.0 × 10(-6) to 30 × 10(-4)mol L(-1) with a detection limit of 2.3 × 10(-6) mol L(-1), and a sensitivity of 150 µA mM(-1) cm(-2). The biosensor response was steady for 28 successive measurements completed in a period of 5h and retained ~90% of the original response even after four weeks when stored at 4 °C. The biosensor was successfully applied for the determination of alcohol in commercial samples and its performance was validated by comparing with the data obtained by GC analyses of the samples.

Keywords: Alcohol; Alcohol oxidase; Biosensor; Direct electron transfer; Ferrocene; Horseradish peroxidase.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Alcohol Oxidoreductases / chemistry*
  • Biosensing Techniques / instrumentation*
  • Conductometry / instrumentation*
  • Electrodes*
  • Enzymes, Immobilized / chemistry
  • Equipment Design
  • Equipment Failure Analysis
  • Ethanol / analysis*
  • Ethanol / chemistry
  • Ferrous Compounds / chemistry*
  • Horseradish Peroxidase / chemistry*
  • Metallocenes
  • Multienzyme Complexes / chemistry
  • Reproducibility of Results
  • Sensitivity and Specificity

Substances

  • Enzymes, Immobilized
  • Ferrous Compounds
  • Metallocenes
  • Multienzyme Complexes
  • Ethanol
  • Alcohol Oxidoreductases
  • alcohol oxidase
  • Horseradish Peroxidase
  • ferrocene