Systematic review of mini-implant displacement under orthodontic loading

Int J Oral Sci. 2014 Mar;6(1):1-6. doi: 10.1038/ijos.2013.92. Epub 2013 Dec 20.

Abstract

A growing number of studies have reported that mini-implants do not remain in exactly the same position during treatment, although they remain stable. The aim of this review was to collect data regarding primary displacement immediately straight after loading and secondary displacement over time. A systematic review was performed to investigate primary and secondary displacement. The amount and type of displacement were recorded. A total of 27 studies were included. Sixteen in vitro studies or studies using finite element analysis addressed primary displacement, and nine clinical studies and two animal studies addressed secondary displacement. Significant primary displacement was detected (6.4-24.4 µm) for relevant orthodontic forces (0.5-2.5 N). The mean secondary displacement ranged from 0 to 2.7 mm for entire mini-implants. The maximum values for each clinical study ranged from 1.0 to 4.1 mm for the head, 1.0 to 1.5 for the body and 1.0 to 1.92 mm for the tail part. The most frequent type of movement was controlled tipping or bodily movement. Primary displacement did not reach a clinically significant level. However, clinicians can expect relevant secondary displacement in the direction of force. Consequently, decentralized insertion within the inter-radicular space, away from force direction, might be favourable. More evidence is needed to provide quantitative recommendations.

Publication types

  • Review
  • Systematic Review

MeSH terms

  • Dental Implants*
  • Humans
  • Miniaturization
  • Orthodontic Anchorage Procedures / instrumentation*
  • Orthodontic Anchorage Procedures / methods
  • Stress, Mechanical

Substances

  • Dental Implants