Purpose: This paper shows the trends from 2001 to 2010 of per caput and collective effective dose (S) to the Emilia-Romagna population due to radiation exposure from projection radiology (PR) and computed tomography (CT), calculated according to both ICRP60 and ICRP103 tissue weighting factors.
Materials and methods: The frequency of examinations and dose calculations were based on data provided directly by Emilia-Romagna Health Trusts. In particular, effective doses were evaluated using the tissue weighting (w T) factors reported both in ICRP60 (w T,60) and in ICRP103 (w T,103).
Results: A decrease in the frequency of PR skull examinations and an increase in the frequency of mammography, CT of the abdomen, chest, and head-neck were found during the decade. In 2010, the PR/CT procedures contributed 75.4 %/24.6 % to examination frequency and approximately 10 %/90 % to dose; S was 6,169.2 man Sv when w T,60 was used and 5,855.1-6,665.5 man Sv when w T,103 in two different mathematical models was utilised.
Conclusions: Dose estimates pre- and post-ICRP103 must be compared carefully, because changes due to different radiological practices could be confused with changes due to the use of different w T's. In general, dose evaluations with the use of w T,60 until 2007 and w T,103 from 2008 seem to be consistent and coherent.