Mechanical ventilation and thoracic artificial lung assistance during mechanical circulatory support with PUCA pump: in silico study

Comput Methods Programs Biomed. 2014 Feb;113(2):642-54. doi: 10.1016/j.cmpb.2013.11.011. Epub 2013 Nov 26.

Abstract

Patients assisted with left ventricular assist device (LVAD) may require prolonged mechanical ventilatory assistance secondary to postoperative respiratory failure. The goal of this work is the study of the interdependent effects LVAD like pulsatile catheter (PUCA) pump and mechanical ventilatory support or thoracic artificial lung (TAL), by the hemodynamic point of view, using a numerical simulator of the human cardiovascular system. In the simulator, different circulatory sections are described using lumped parameter models. Lumped parameter models have been designed to describe the hydrodynamic behavior of both PUCA pump and thoracic artificial lung. Ventricular behavior atrial and septum functions were reproduced using variable elastance model. Starting from simulated pathological conditions we studied the effects produced on some hemodynamic variables by simultaneous PUCA pump, thoracic artificial lung or mechanical ventilation assistance. Thoracic artificial lung was applied in parallel or in hybrid mode. The effects of mechanical ventilation have been simulated by changing mean intrathoracic pressure value from -4 mmHg to +5 mmHg. The hemodynamic variables observed during the simulations, in different assisted conditions, were: left and right ventricular end systolic (diastolic) volume, systolic/diastolic aortic pressure, mean pulmonary arterial pressure, left and right mean atrial pressure, mean systemic venous pressure and the total blood flow. Results show that the application of PUCA (without mechanical ventilatory assistance) increases the total blood flow, reduces the left ventricular end systolic volume and increases the diastolic aortic pressure. Parallel TAL assistance increases the right ventricular end diastolic (systolic) volume reduction both when PUCA is switched "ON" and both when PUCA is switched "OFF". By switching "OFF" the PUCA pump, it seems that parallel thoracic artificial lung assistance produces a greater cardiac output (respect to hybrid TAL assistance). Results concerning PUCA and TAL interaction produced by simulations cannot be compared with "in vivo" results since they are not presented in literature. But results concerning the effects produced by LVAD and mechanical ventilation have a trend consistent with those presented in literature.

Keywords: CO; CVS; Circulatory system; HF; HR; Hemodynamics; ICUs; LAP (RAP); LVAD; LVESV (LVEDV); MCS; MV; Mechanical ventilation; NL; Numerical model; PAP; PQ; PUCA; P–V; QRS; QT; REMATCH; RVESV (RVEDV); TAL; TBF; Thoracic artificial lung assistance; VADs; Ventricular assist device; cardiac output; cardiovascular system; combination of three of the graphical deflections seen on a typical electrocardiogram; heart failure; heart rate; intensive care units; interval time between the beginning of atrial depolarization and the beginning of ventricular depolarization (in ECG); interval time between the onset of ventricular depolarization and the end of ventricular repolarization (in electrocardiogram ECG); left ventricular assist device; left ventricular end systolic (diastolic) volume; mean left (right) atrial pressure; mean pulmonary arterial pressure; mechanical circulatory support; mechanical ventilation; natural lung; pressure–volume; pulsatile catheter pump; randomized evaluation of mechanical assistance for the treatment of congestive heart failure; right ventricular end systolic (diastolic) volume; thoracic artificial lung; total blood flow (TBF=left ventricular output flow+PUCA output flow); ventricular assist devices.

MeSH terms

  • Artificial Organs*
  • Blood Circulation*
  • Catheters
  • Computer Simulation
  • Humans
  • Hydrodynamics
  • Lung / physiology*
  • Models, Theoretical
  • Respiration, Artificial*