Dose reduction in dynamic CT stress myocardial perfusion imaging: comparison of 80-kV/370-mAs and 100-kV/300-mAs protocols

Eur Radiol. 2014 Mar;24(3):748-55. doi: 10.1007/s00330-013-3063-z. Epub 2013 Nov 22.

Abstract

Objectives: To determine the effect of reduced 80-kV tube voltage with increased 370-mAs tube current on radiation dose, image quality and estimated myocardial blood flow (MBF) of dynamic CT stress myocardial perfusion imaging (CTP) in patients with a normal body mass index (BMI) compared with a 100-kV and 300-mAs protocol.

Methods: Thirty patients with a normal BMI (<25 kg/m(2)) with known or suspected coronary artery disease underwent adenosine-stress dual-source dynamic CTP. Patients were randomised to 80-kV/370-mAs (n = 15) or 100-kV/300-mAs (n = 15) imaging. Maximal enhancement and noise of the left ventricular (LV) cavity, contrast-to-noise ratio (CNR) and MBF of the two groups were compared.

Results: Imaging with 80-kV/370-mAs instead of 100-kV/300-mAs was associated with 40% lower radiation dose (mean dose-length product, 359 ± 66 vs 628 ± 112 mGy[Symbol: see text]cm; P < 0.001 ) with no significant difference in CNR (34.5 ± 13.4 vs 33.5 ± 10.4; P = 0.81) or MBF in non-ischaemic myocardium (0.95 ± 0.20 vs 0.99 ± 0.25 ml/min/g; P = 0.66). Studies obtained using 80-kV/370-mAs were associated with 30.9% higher maximal enhancement (804 ± 204 vs 614 ± 115 HU; P < 0.005), and 31.2% greater noise (22.7 ± 3.5 vs 17.4 ± 2.6; P < 0.001).

Conclusions: Dynamic CTP using 80-kV/370-mA instead of 100-kV/300-mAs allowed 40% dose reduction without compromising image quality or MBF. Tube voltage of 80-kV should be considered for individuals with a normal BMI.

Key points: • CT stress perfusion imaging (CTP) is increasingly used to assess myocardial function. • Dynamic CTP is feasible at 80-kV in patients with normal BMI. • An 80-kV/370-mAs protocol allows 40% dose reduction compared with 100-kV/300-mAs. • Contrast-to-noise ratio and myocardial blood flow of the two protocols were comparable.

Publication types

  • Comparative Study
  • Randomized Controlled Trial
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adenosine
  • Aged
  • Artifacts
  • Body Mass Index
  • Coronary Angiography / methods*
  • Coronary Artery Disease / diagnostic imaging*
  • Coronary Circulation
  • Exercise Test / methods
  • Female
  • Humans
  • Male
  • Middle Aged
  • Myocardial Perfusion Imaging / methods*
  • Radiation Dosage
  • Tomography, X-Ray Computed / methods*
  • Vasodilator Agents

Substances

  • Vasodilator Agents
  • Adenosine