One step polymerizing technique for fabricating a hollow obturator

J Prosthodont Res. 2013 Oct;57(4):294-7. doi: 10.1016/j.jpor.2013.08.003. Epub 2013 Oct 2.

Abstract

Purpose: Although a closed hollow obturator is often applied to post maxillectomy patients, it has a few problems such as complexity of fabrication and water leakage to inside. A one step curing technique to fabricate a closed hollow obturator by constructing a small hollow bulb made by two thermoplastic resin sheets is described in the present report.

Methods: In the one step curing technique, after dewaxing the wax denture fabricated conventionally, one size smaller hollow body was fabricated with two thermoplastic resin sheets and set into the investment mold as a core. Then the circumferential part of obturator was cured by the pour type resin. This technique was used to fabricate an obturator prosthesis in a 60-year-old post-maxillectomy patient. The weight of this obturator was well controlled and the definitive prosthesis weighed 22 g. At a one year follow-up, the obturator fared well without any water leakage or breakage.

Conclusions: This technique allows the fabricator to control the thickness and weight of the obturator by the amount of relief provided by the hollow bulb. It also rectifies the disadvantages of the closed hollow obturator such as water leakage and complexity of fabrication.

Keywords: Closed hollow obturator; Maxillofacial prosthodontics; Obturator; Thermoform.

Publication types

  • Case Reports

MeSH terms

  • Carcinoma / rehabilitation
  • Dental Prosthesis Design / methods*
  • Denture Design
  • Female
  • Follow-Up Studies
  • Humans
  • Maxillary Neoplasms / rehabilitation
  • Middle Aged
  • Palatal Obturators*
  • Polymerization*
  • Prosthodontics / methods*
  • Time Factors