Effects of a pressure release on virus retention with the Ultipor DV20 membrane

Biotechnol Bioeng. 2014 Mar;111(3):545-51. doi: 10.1002/bit.25112. Epub 2013 Sep 25.

Abstract

Recent data have shown that a temporary release in the transmembrane pressure can cause a significant increase in virus transmission through a number of commercial virus filters. The objective of this work was to study the effect of a pressure release on retention of the bacteriophage ΦX174 by the Ultipor DV20 membrane, with phage capture within the membrane visualized by confocal microscopy. Phage challenge tests showed a significant transient increase in phage transmission (typically by an order of magnitude) immediately after a pressure release. This transient increase was not due to any damage to the filter or to the presence of a back-flow (from permeate to feed). Confocal images demonstrated that the pressure release caused the migration of previously captured bacteriophage further into the depth of the filter. Data were analyzed using a modified internal polarization model, with the results providing important insights into the factors controlling virus retention during virus filtration.

Keywords: downstream processing; filtration; virus clearance; virus filtration.

MeSH terms

  • Bacteriophage phi X 174 / isolation & purification*
  • Filtration / methods*
  • Hydrostatic Pressure*
  • Membranes