A semi-automatic microextraction in packed sorbent, using a digitally controlled syringe, combined with ultra-high pressure liquid chromatography as a new and ultra-fast approach for the determination of prenylflavonoids in beers

J Chromatogr A. 2013 Aug 23:1304:42-51. doi: 10.1016/j.chroma.2013.06.072. Epub 2013 Jul 2.

Abstract

In this work a highly selective and sensitive analytical procedure based on semi-automatic microextraction by packed sorbents (MEPS) technique, using a new digitally controlled syringe (eVol(®)) combined with ultra-high pressure liquid chromatography (UHPLC), is proposed to determine the prenylated chalcone derived from the hop (Humulus lupulus L.), xanthohumol (XN), and its isomeric flavonone isoxanthohumol (IXN) in beers. Extraction and UHPLC parameters were accurately optimized to achieve the highest recoveries and to enhance the analytical characteristics of the method. Important parameters affecting MEPS performance, namely the type of sorbent material (C2, C8, C18, SIL, and M1), elution solvent system, number of extraction cycles (extract-discard), sample volume, elution volume, and sample pH, were evaluated. The optimal experimental conditions involves the loading of 500μL of sample through a C18 sorbent in a MEPS syringe placed in the semi-automatic eVol(®) syringe followed by elution using 250μL of acetonitrile (ACN) in a 10 extractions cycle (about 5min for the entire sample preparation step). The obtained extract is directly analyzed in the UHPLC system using a binary mobile phase composed of aqueous 0.1% formic acid (eluent A) and ACN (eluent B) in the gradient elution mode (10min total analysis). Under optimized conditions good results were obtained in terms of linearity within the established concentration range with correlation coefficients (R) values higher than 0.986, with a residual deviation for each calibration point below 12%. The limit of detection (LOD) and limit of quantification (LOQ) obtained were 0.4ngmL(-1) and 1.0ngmL(-1) for IXN, and 0.9ngmL(-1) and 3.0ngmL(-1) for XN, respectively. Precision was lower than 4.6% for IXN and 8.4% for XN. Typical recoveries ranged between 67.1% and 99.3% for IXN and between 74.2% and 99.9% for XN, with relative standard deviations %RSD no larger than 8%. The applicability of the proposed analytical procedure in commercial beers, revealed the presence of both target prenylchalcones in all samples being IXN the most abundant with concentration of between 0.126 and 0.200μgmL(-1).

Keywords: Beer; Isoxanthohumol; Microextraction by packed sorbent (MEPS); Ultra High Performance Liquid Chromatography (UHPLC); Xanthohumol.

Publication types

  • Research Support, Non-U.S. Gov't
  • Validation Study

MeSH terms

  • Beer / analysis*
  • Chalcone / analysis
  • Chromatography, High Pressure Liquid / economics
  • Chromatography, High Pressure Liquid / methods*
  • Flavonoids / analysis*
  • Humulus / chemistry
  • Limit of Detection
  • Propiophenones / analysis*
  • Solid Phase Microextraction / economics
  • Solid Phase Microextraction / methods*
  • Time Factors
  • Xanthones / analysis*

Substances

  • Flavonoids
  • Propiophenones
  • Xanthones
  • isoxanthohumol
  • Chalcone
  • xanthohumol