Biomechanical evaluation of three different fixation methods of the Chevron osteotomy of the olecranon: an analysis with Roentgen Stereophotogrammatic Analysis

Clin Biomech (Bristol, Avon). 2013 Aug;28(7):752-6. doi: 10.1016/j.clinbiomech.2013.06.011. Epub 2013 Jul 8.

Abstract

Background: In this study three different methods for fixating the Chevron osteotomy of the olecranon are evaluated. Transcortical fixed Kirschner wires with a tension band, a large cancellous screw with a tension band, and a large cancellous screw alone are compared using Roentgen Stereophotogrammatic Analysis (RSA).

Methods: The different fixation methods were tested in 17 cadaver specimens by applying increasing repetitive force to the triceps tendon. Forces applied were 200N, 350N, and 500N. Translation and rotation of the osteotomy were recorded using Roentgen Stereophotogrammatic Analysis.

Findings: Both the fixations with a cancellous screw with tension band and with bi-cortical placed Kirschner wires with a tension band provide enough stability to withstand the forces of normal daily use.

Interpretation: Since fixation with a cancellous screw with tension band is a fast and easy method and is related to minimal soft tissue damage this method can preferably be used for fixation of a Chevron osteotomy of the olecranon.

Keywords: Approach; Chevron osteotomy; Elbow; Roentgen Stereophotogrammatic Analysis.

Publication types

  • Evaluation Study

MeSH terms

  • Aged
  • Aged, 80 and over
  • Biomechanical Phenomena
  • Bone Density
  • Bone Screws
  • Bone Wires
  • Cadaver
  • Female
  • Fracture Fixation, Internal / methods*
  • Humans
  • Internal Fixators
  • Male
  • Olecranon Process / diagnostic imaging*
  • Olecranon Process / injuries
  • Olecranon Process / physiopathology
  • Olecranon Process / surgery*
  • Osteotomy / methods*
  • Photogrammetry / methods*
  • Radiography