Stingray balloon used in slender percutaneous coronary intervention for chronic total occlusion

J Invasive Cardiol. 2013 Jul;25(7):E155-8.

Abstract

Slender chronic total occlusion (CTO) percutaneous coronary intervention (PCI) using 5 Fr radial Ikari catheter is possible in simple CTO cases. We report a case where we initially thought the LAD CTO was short and easy, but we found that the CTO had a considerable amount of calcium and also some tortuosity, making simple wire crossing impossible. We used a Stingray balloon to perform re-entry by tracking the balloon over an Ultimate Bros 3 gram wire using an extension wire. We successfully punctured into true lumen and completed stenting through a slender 5 Fr system. This case demonstrates the beauty of combining the advances in CTO PCI from the East and the West together and also demonstrates the possibility of using the Stingray system in a 5 Fr guiding catheter.

Publication types

  • Case Reports

MeSH terms

  • Angioplasty, Balloon, Coronary / instrumentation*
  • Chronic Disease
  • Coronary Angiography
  • Coronary Occlusion / diagnostic imaging
  • Coronary Occlusion / therapy*
  • Humans
  • Japan
  • Middle Aged
  • Percutaneous Coronary Intervention / instrumentation*
  • Percutaneous Coronary Intervention / methods*
  • Treatment Outcome
  • United States