Oxygenation-sensitive cardiovascular magnetic resonance

J Cardiovasc Magn Reson. 2013 May 24;15(1):43. doi: 10.1186/1532-429X-15-43.

Abstract

Oxygenation-sensitive cardiovascular magnetic resonance (CMR) is a non-contrast technique that allows the non-invasive assessment of myocardial oxygenation. It capitalizes on the fact that deoxygenated hemoglobin in blood can act as an intrinsic contrast agent, changing proton signals in a fashion that can be imaged to reflect the level of blood oxygenation. Increases in O(2) saturation increase the BOLD imaging signal (T2 or T2*), whereas decreases diminish it. This review presents the basic concepts and limitations of the BOLD technique, and summarizes the preclinical and clinical studies in the assessment of myocardial oxygenation with a focus on recent advances. Finally, it provides future directions and a brief look at emerging techniques of this evolving CMR field.

Publication types

  • Research Support, Non-U.S. Gov't
  • Review

MeSH terms

  • Animals
  • Cardiovascular Diseases / diagnosis*
  • Cardiovascular Diseases / metabolism
  • Humans
  • Magnetic Resonance Angiography / methods
  • Magnetic Resonance Imaging / methods*
  • Microcirculation
  • Myocardium / metabolism
  • Oxygen / blood*

Substances

  • Oxygen