Cardiovascular magnetic resonance artefacts

J Cardiovasc Magn Reson. 2013 May 22;15(1):41. doi: 10.1186/1532-429X-15-41.

Abstract

The multitude of applications offered by CMR make it an increasing popular modality to study the heart and the surrounding vessels. Nevertheless the anatomical complexity of the chest, together with cardiac and respiratory motion, and the fast flowing blood, present many challenges which can possibly translate into imaging artefacts. The literature is wide in terms of papers describing specific MR artefacts in great technical detail. In this review we attempt to summarise, in a language accessible to a clinical readership, some of the most common artefacts found in CMR applications. It begins with an introduction of the most common pulse sequences, and imaging techniques, followed by a brief section on typical cardiovascular applications. This leads to the main section on common CMR artefacts with examples, a short description of the mechanisms behind them, and possible solutions.

Publication types

  • Research Support, Non-U.S. Gov't
  • Review

MeSH terms

  • Artifacts*
  • Cardiovascular Diseases / diagnosis*
  • Humans
  • Magnetic Resonance Imaging / methods*