The effects of handling and storage on magnesium based implants--first results

Mater Sci Eng C Mater Biol Appl. 2013 Jul 1;33(5):3010-7. doi: 10.1016/j.msec.2013.03.034. Epub 2013 Mar 26.

Abstract

The present work aimed to investigate the influence of acetone and formalin as well as the duration and type of storage on magnesium based implants by means of microscopic, μ-computed tomographic, scanning electron microscopic, EDX and metallographic investigations. In contrast to storing in acetone, storage in formalin led to an increase in surface to volume ratio, and a decrease of the volume and the density. The various types of storage exerted no differing effects on the implants but with increasing storage duration, a spreading of oxygen rich areas on the surface, increased precipitations and a decrease in grain size could be observed.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Acetone / chemistry
  • Formaldehyde / chemistry
  • Magnesium*
  • Microscopy, Electron, Scanning
  • Prostheses and Implants*
  • Tomography, X-Ray Computed

Substances

  • Acetone
  • Formaldehyde
  • Magnesium