Effect of flip angle on the accuracy and repeatability of hepatic proton density fat fraction estimation by complex data-based, T1-independent, T2*-corrected, spectrum-modeled MRI

J Magn Reson Imaging. 2014 Feb;39(2):440-7. doi: 10.1002/jmri.24153. Epub 2013 Apr 17.

Abstract

Purpose: To evaluate the effect of flip angle (FA) on accuracy and within-examination repeatability of hepatic proton-density fat fraction (PDFF) estimation with complex data-based magnetic resonance imaging (MRI).

Materials and methods: PDFF was estimated at 3T in 30 subjects using two sets of five MRI sequences with FA from 1° to 5° in each set. One set used 7 msec repetition time and acquired 6 echoes (TR7/E6); the other used 14 msec and acquired 12 echoes (TR14/E12). For each FA in both sets the accuracy of MRI-PDFF was assessed relative to MR spectroscopy (MRS)-PDFF using four regression parameters (slope, intercept, average bias, R(2) ). Each subject had four random sequences repeated; within-examination repeatability of MRI-PDFF for each FA was assessed with intraclass correlation coefficient (ICC). Pairwise comparisons were made using bootstrap-based tests.

Results: Most FAs provided high MRI-PDFF estimation accuracy (intercept range -1.25 to 0.84, slope 0.89-1.06, average bias 0.24-1.65, R(2) 0.85-0.97). Most comparisons of regression parameters between FAs were not significant. Informally, in the TR7/E6 set, FAs of 2° and 3° provided the highest accuracy, while FAs of 1° and 5° provided the lowest. In the TR14/E12 set, accuracy parameters did not differ consistently between FAs. FAs in both sets provided high within-examination repeatability (ICC range 0.981-0.998).

Conclusion: MRI-PDFF was repeatable and, for most FAs, accurate in both sequence sets. In the TR7/E6 sequence set, FAs of 2° and 3° informally provided the highest accuracy. In the TR14/E12 sequence set, all FAs provided similar accuracy.

Keywords: accuracy; flip angle; magnetic resonance imaging; proton-density fat fraction; repeatability.

Publication types

  • Research Support, N.I.H., Extramural
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adiposity / physiology*
  • Adolescent
  • Adult
  • Aged
  • Algorithms*
  • Artifacts*
  • Female
  • Humans
  • Image Interpretation, Computer-Assisted / methods*
  • Liver / physiology*
  • Magnetic Resonance Imaging / methods*
  • Male
  • Middle Aged
  • Observer Variation
  • Protons
  • Reproducibility of Results
  • Sensitivity and Specificity
  • Young Adult

Substances

  • Protons