The estimated sensitivity and specificity of compartment pressure monitoring for acute compartment syndrome

J Bone Joint Surg Am. 2013 Apr 17;95(8):673-7. doi: 10.2106/JBJS.K.01731.

Abstract

Background: The aim of our study was to document the estimated sensitivity and specificity of continuous intracompartmental pressure monitoring for the diagnosis of acute compartment syndrome.

Methods: From our prospective trauma database, we identified all patients who had sustained a tibial diaphyseal fracture over a ten-year period. A retrospective analysis of 1184 patients was performed to record and analyze the documented use of continuous intracompartmental pressure monitoring and the use of fasciotomy. A diagnosis of acute compartment syndrome was made if there was escape of muscles at fasciotomy and/or color change in the muscles or muscle necrosis intraoperatively. A diagnosis of acute compartment syndrome was considered incorrect if it was possible to close the fasciotomy wounds primarily at forty-eight hours. The absence of acute compartment syndrome was confirmed by the absence of neurological abnormality or contracture at the time of the latest follow-up.

Results: Of 979 monitored patients identified, 850 fit the inclusion criteria with a mean age of thirty-eight years (range, twelve to ninety-four years), and 598 (70.4%) were male (p < 0.001). A total of 152 patients (17.9%) underwent fasciotomy for the treatment of acute compartment syndrome: 141 had acute compartment syndrome (true positives), six did not have it (false positives), and five underwent fasciotomy despite having a normal differential pressure reading, with subsequent operative findings consistent with acute compartment syndrome (false negatives). Of the 698 patients (82.1%) who did not undergo fasciotomy, 689 had no evidence of any late sequelae of acute compartment syndrome (true negatives) at a mean follow-up time of fifty-nine weeks. The estimated sensitivity of intracompartmental pressure monitoring for suspected acute compartment syndrome was 94%, with an estimated specificity of 98%, an estimated positive predictive value of 93%, and an estimated negative predictive value of 99%.

Conclusions: The estimated sensitivity and specificity of continuous intracompartmental pressure monitoring for the diagnosis of acute compartment syndrome following tibial diaphyseal fracture are high; continuous intracompartmental pressure monitoring should be considered for patients at risk for acute compartment syndrome.

MeSH terms

  • Adolescent
  • Adult
  • Aged
  • Aged, 80 and over
  • Anterior Compartment Syndrome / diagnosis*
  • Anterior Compartment Syndrome / etiology
  • Anterior Compartment Syndrome / surgery
  • Child
  • Diaphyses / injuries
  • Fasciotomy
  • Female
  • Humans
  • Male
  • Middle Aged
  • Monitoring, Physiologic
  • Patient Selection
  • Retrospective Studies
  • Sensitivity and Specificity
  • Tibial Fractures / complications*
  • Tibial Fractures / diagnosis
  • Tibial Fractures / surgery