Coupling ion-exchangers with inexpensive activated carbon fiber electrodes to enhance the performance of capacitive deionization cells for domestic wastewater desalination

Water Res. 2013 May 1;47(7):2523-30. doi: 10.1016/j.watres.2013.02.037. Epub 2013 Feb 27.

Abstract

A capacitive deionization (CDI) cell was built with electrodes made of an inexpensive commercial activated carbon fiber (ACF), and then modified by incorporating ion-exchangers into the cell compartment. Three modified CDI designs were tested: MCDI - a CDI with electrodes covered by ion-exchange membranes (IEMs) of the same polarity, FCDI - a CDI with electrodes covered by ion-exchange felts (IEFs), and R-MCDI - an MCDI with cell chamber packed with ion-exchange resin (IER) granules. The cell was operated in the batch reactor mode with an initial salt concentration of 1000 mg/L NaCl, a typical level of domestic wastewater. The desalination tests involved investigations of two consecutive operation stages of CDIs: electrical adsorption (at an applied voltage of 1.2 V) and desorption [including short circuit (SC) desorption and discharge (DC) desorption]. The R-MCDI showed the highest electric adsorption as measured in the present study by desalination rate [670 ± 20 mg/(L h)] and salt removal efficiency (90 ± 1%) at 60 min, followed by the MCDI [440 ± 15 mg/(L h) and 60 ± 2%, respectively]. The superior desalination performance of the R-MCDI over other designs was also affirmed by its highest charge efficiency (110 ± 7%) and fastest desorption rates at both the SC [1960 ± 15 mg/(L·h)] and DC [3000 ± 20 mg/(L·h)] modes. The desalination rate and salt removal efficiency of the R-MCDI increased from ∼270 mg/(L h) and 83% to ∼650 mg/(L h) and 98% respectively when the applied voltage increased from 0.6 V to 1.4 V, while decreased slightly when lowering the salt water flow rate that fed into the cell. The packing of IER granules in the R-MCDI provided additional surface area for ions transfer; meanwhile, according to the results of electrochemical impedance spectroscopy (EIS) analysis, it substantially lower down the R-MCDI's ohmic resistance, resulting in improved desalination performance.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adsorption
  • Carbon / chemistry*
  • Carbon / economics
  • Carbon Fiber
  • Charcoal / chemistry*
  • Charcoal / economics
  • Electricity
  • Electrodes / economics
  • Family Characteristics
  • Ion Exchange
  • Ion Exchange Resins / chemistry*
  • Membranes, Artificial
  • Rheology
  • Salinity*
  • Sodium Chloride / analysis
  • Wastewater / chemistry*
  • Wastewater / economics
  • Water Purification / economics*
  • Water Purification / methods*

Substances

  • Carbon Fiber
  • Ion Exchange Resins
  • Membranes, Artificial
  • Waste Water
  • Charcoal
  • Sodium Chloride
  • Carbon