Abstract

Background and aim of the study: A number of sutureless bioprosthetic aortic valves have been recently introduced in clinical practice, their main advantage being a reduction in the aortic cross-clamp time (AXCT). The study aim was to investigate if AXCT was a determinant of cardiovascular morbidity in patients undergoing surgical aortic valve replacement (AVR) to treat aortic valve stenosis, and to identify any subset of patients who might benefit from a reduction in AXCT.

Methods: A retrospective analysis was conducted of 979 consecutive patients with aortic valve stenosis who underwent surgical AVR. The AXCT was analyzed as an independent predictor of severe cardiovascular morbidity, defined as the presence of a low cardiac output, stroke, acute kidney injury, or operative mortality. Subgroups of patients who benefited more from a reduction in AXCT were investigated.

Results: The AXCT was an independent predictor of severe cardiovascular morbidity, with an increased risk of 1.4% per 1 min increase. Patients with a left ventricular ejection fraction < or = 40%, and also diabetic patients, showed the most relevant clinical benefits induced by a reduction in AXCT.

Conclusion: In selected patient populations at high risk of systolic dysfunction, the use of sutureless aortic valve bioprostheses may be considered. However, the routine use of such bioprostheses should be pondered within a cost-benefit analysis.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Aged
  • Aged, 80 and over
  • Aorta / surgery*
  • Aortic Valve / physiopathology
  • Aortic Valve / surgery*
  • Aortic Valve Stenosis / mortality
  • Aortic Valve Stenosis / physiopathology
  • Aortic Valve Stenosis / surgery*
  • Bioprosthesis*
  • Constriction
  • Female
  • Heart Valve Prosthesis Implantation / adverse effects
  • Heart Valve Prosthesis Implantation / instrumentation*
  • Heart Valve Prosthesis Implantation / methods*
  • Heart Valve Prosthesis Implantation / mortality
  • Heart Valve Prosthesis*
  • Humans
  • Logistic Models
  • Male
  • Middle Aged
  • Multivariate Analysis
  • Odds Ratio
  • Prosthesis Design
  • Retrospective Studies
  • Risk Assessment
  • Risk Factors
  • Stroke Volume
  • Suture Techniques
  • Time Factors
  • Treatment Outcome
  • Ventricular Function, Left