Abstract
Intracranial arteriovenous posterior circulation malformation was planned to embolize by onyx injection after acute coil embolization of ruptured flow-realeted aneurysm of posterior cerebral artery. Control angiography revealed completely embolized malformation with normal vessel patency at the end of procedure. There were no adverse events related to this procedure and no neurologic deficit at the discharge.
MeSH terms
-
Adult
-
Aneurysm, Ruptured / complications*
-
Aneurysm, Ruptured / therapy
-
Cerebral Angiography
-
Dimethyl Sulfoxide / therapeutic use*
-
Elective Surgical Procedures
-
Embolization, Therapeutic*
-
Female
-
Humans
-
Intracranial Aneurysm / complications*
-
Intracranial Aneurysm / therapy
-
Intracranial Arteriovenous Malformations / complications
-
Intracranial Arteriovenous Malformations / therapy*
-
Polyvinyls / therapeutic use*
-
Posterior Cerebral Artery / abnormalities*
-
Posterior Cerebral Artery / diagnostic imaging
Substances
-
Onyx copolymer
-
Polyvinyls
-
Dimethyl Sulfoxide