Thigh pain, subsidence and survival using a short cementless femoral stem with pure metaphyseal fixation at minimum 9-year follow-up

Orthop Traumatol Surg Res. 2013 Feb;99(1):30-6. doi: 10.1016/j.otsr.2012.09.016. Epub 2012 Dec 19.

Abstract

Background: Short femoral stems designed to spare bone stock and improve load transfer at the proximal femur level have been introduced in recent years. However, little is known on the long-term outcomes of these stems.

Hypothesis: Short cementless stems have low rate of thigh pain and subsidence as well as few revision needs at mid-term follow-up.

Materials and methods: We prospectively followed 64 patients (72 hips) undergoing total hip arthroplasty with a femoral stem designed to achieve a pure metaphyseal fixation. Patients with hip fracture, femoral neck deformity and osteoporotic bone were excluded. Clinical evaluations were performed annually until the last follow-up, a minimum of 9 years after surgery. At each follow-up, implant positioning was assessed on conventional plain films with a computer assisted radiographic evaluation.

Results: The Harris hip score improved from 43 points (range 19-50) before surgery to 88 points (range 73-100) at the final follow-up (P=0.001), and the Womac score averaged 47 points (range 35-56 points) preoperatively and 76 points (range 63-84) at the last follow-up (P=0.001). Thigh pain was reported by five patients (8%) at the 2-year follow-up, but only in two (3%) was still present, and related to the prosthesis, at last follow-up. Computer assisted radiographic analysis showed a neutral alignment of the stem in 56% of cases, a varus-valgus alignment less than 5° in 36% and equal to 5° in 8%. Stem subsidence was observed in 12 hips but was less than 4mm in all cases (range 0-3mm). Calcar height remained unchanged over time. Adaptive bone remodelling, including proximal bone resorption and distal cortical hypertrophy were not observed at follow-up. No patients had aseptic loosening of the stem nor were radiolucent lines detectable at the level of the porous coating. Survivorship analysis showed a 100% survival rate of the stem at nine years.

Discussion: This study showed that a femoral stem designed to achieve a pure metaphyseal fixation may obtain, in a selected group of patients with adequate bone quality, satisfactory clinical outcomes without compromising implant stability. The limited periprosthetic bone remodelling observed after a minimum of 9 years follow-up suggests that this type of implant may improve mechanical stresses on host bone compared with standard stems requiring diaphyseal fixation.

Level of evidence: Level IV. Historical series.

MeSH terms

  • Arthroplasty, Replacement, Hip*
  • Follow-Up Studies
  • Hip Prosthesis*
  • Humans
  • Prospective Studies
  • Prosthesis Design
  • Thigh
  • Treatment Outcome