Aortic valve replacement: is porcine or bovine valve better?

Interact Cardiovasc Thorac Surg. 2013 Mar;16(3):361-73. doi: 10.1093/icvts/ivs447. Epub 2012 Dec 4.

Abstract

A best evidence topic in cardiac surgery was written according to a structured protocol. The question addressed was: 'Is porcine or bovine valve better for aortic valve replacement?' Altogether, 562 papers were found using the reported search, of which 15 represented the best evidence to answer the question. All papers represent either level 1 or 2 evidence. The authors, journal, date, country of publication, patient group studied, study type, relevant outcomes and results of these papers are tabulated. This best evidence paper includes 9880 patients from 1974-2006 to compare both valve types. All studies compared either all or some of the following outcomes: complication, durability, mortality, functional status and haemodynamic function. Ten of 15 papers assessed the complication profile due to aortic valve replacement in both valve types. Four papers concluded that bovine valves are superior, whereas only one favoured porcine valves. Five papers showed a similar complication profile between both valves. Six of 15 papers commented on valve durability. Both porcine and bovine valve groups have two papers each to support their superiority in valve durability. Two papers demonstrated similar durability in both valves. There are 11 papers comparing the postoperative mortality. We suggest that there is no difference in mortality profile as eight papers showed that both valves had similar mortality profiles. Two papers supported bovine valve and one paper supported porcine valve in this aspect. There were four papers assessing the postoperative functional status, with three papers suggesting that both valve types had similar clinical improvement postoperatively. Eleven papers compared the haemodynamic function. Nine papers were in favour of bovine valves. Two papers demonstrated similar haemodynamic profiles in both valves. In conclusion, the bovine valve is superior in its complication and haemodynamic profiles. Both bovine and porcine valves have comparable results with regard to the mortality, postoperative functional status and valve durability. Significant variability between the valve manufacturers, study designs, study period and patient population in the above studies impose limitations to the comparison of both valves.

Publication types

  • Review

MeSH terms

  • Aged
  • Animals
  • Aortic Valve / physiopathology
  • Aortic Valve / surgery*
  • Aortic Valve Stenosis / mortality
  • Aortic Valve Stenosis / physiopathology
  • Aortic Valve Stenosis / surgery*
  • Benchmarking
  • Bioprosthesis*
  • Cattle
  • Evidence-Based Medicine
  • Female
  • Heart Valve Prosthesis Implantation / adverse effects
  • Heart Valve Prosthesis Implantation / instrumentation*
  • Heart Valve Prosthesis Implantation / mortality
  • Heart Valve Prosthesis*
  • Hemodynamics
  • Humans
  • Male
  • Prosthesis Design
  • Prosthesis Failure
  • Swine
  • Time Factors
  • Treatment Outcome