Stereoelectroencephalography: surgical methodology, safety, and stereotactic application accuracy in 500 procedures

Neurosurgery. 2013 Mar;72(3):353-66; discussion 366. doi: 10.1227/NEU.0b013e31827d1161.

Abstract

Background: Stereoelectroencephalography (SEEG) methodology, originally developed by Talairach and Bancaud, is progressively gaining popularity for the presurgical invasive evaluation of drug-resistant epilepsies.

Objective: To describe recent SEEG methodological implementations carried out in our center, to evaluate safety, and to analyze in vivo application accuracy in a consecutive series of 500 procedures with a total of 6496 implanted electrodes.

Methods: Four hundred nineteen procedures were performed with the traditional 2-step surgical workflow, which was modified for the subsequent 81 procedures. The new workflow entailed acquisition of brain 3-dimensional angiography and magnetic resonance imaging in frameless and markerless conditions, advanced multimodal planning, and robot-assisted implantation. Quantitative analysis for in vivo entry point and target point localization error was performed on a sub--data set of 118 procedures (1567 electrodes).

Results: The methodology allowed successful implantation in all cases. Major complication rate was 12 of 500 (2.4%), including 1 death for indirect morbidity. Median entry point localization error was 1.43 mm (interquartile range, 0.91-2.21 mm) with the traditional workflow and 0.78 mm (interquartile range, 0.49-1.08 mm) with the new one (P < 2.2 × 10). Median target point localization errors were 2.69 mm (interquartile range, 1.89-3.67 mm) and 1.77 mm (interquartile range, 1.25-2.51 mm; P < 2.2 × 10), respectively.

Conclusion: SEEG is a safe and accurate procedure for the invasive assessment of the epileptogenic zone. Traditional Talairach methodology, implemented by multimodal planning and robot-assisted surgery, allows direct electrical recording from superficial and deep-seated brain structures, providing essential information in the most complex cases of drug-resistant epilepsy.

MeSH terms

  • Adolescent
  • Adult
  • Algorithms
  • Brain / surgery
  • Cerebral Angiography
  • Child
  • Child, Preschool
  • Drug Resistance
  • Electrodes, Implanted / adverse effects
  • Electroencephalography* / adverse effects
  • Epilepsy / diagnosis
  • Epilepsy / surgery*
  • Female
  • Humans
  • Imaging, Three-Dimensional
  • Magnetic Resonance Imaging
  • Male
  • Middle Aged
  • Multivariate Analysis
  • Neurosurgical Procedures / methods*
  • Robotics
  • Safety
  • Stereotaxic Techniques*
  • Surgery, Computer-Assisted / methods*
  • Young Adult