Computed tomography of the bowel: a prospective comparison study between four techniques

Eur J Radiol. 2013 Jan;82(1):e1-e10. doi: 10.1016/j.ejrad.2012.08.021. Epub 2012 Sep 19.

Abstract

Objectives: The major objective was to prospectively compare the grade of bowel distension obtained with four different computed tomography (CT) techniques dedicated for the examination of the small intestine (CT enteroclysis [CTE] and enterography [CTe]), of the colon (CT with water enema [CT-WE]), or both (CTe with water enema [CTe-WE]). The secondary objective was to assess patients' tolerance toward each CT protocol.

Materials and methods: Recruitment was designed to obtain four groups of the same number of patients (30). Each group corresponded to a specific CT technique, for a total of 120 consecutive outpatients (65 male and 55 female, mean age 51.09 ± 13.36 years). CTE was performed after injection of methylcellulose through a nasojejunal tube, while in the CTe protocol a polyethylene glycol electrolyte solution was orally administered to patients prior to the CT acquisition. In the CT-WE protocol intraluminal contrast (water) was administered only by a rectal enema, while CTe-WE technique included both a rectal water enema and oral ingestion of neutral contrast material to obtain a simultaneous distension of small and large bowel. CT studies were reviewed in consensus by two gastrointestinal radiologists who performed a quantitative and qualitative analysis of bowel distension on a per segment basis. The presence and type of adverse effects were recorded.

Results: CTE provided the best distension of jejunal loops (median diameter 27 mm, range 17-32 mm) when compared to all the other techniques (p<0.0001). The frequency of patients with an adequate distension of the terminal ileum was not significantly different among the four groups (p=0.0608). At both quantitative and qualitative analysis CT-WE and CTe-WE determined a greater and more consistent luminal filling of the large intestine than that provided by both CTE and CTe (p<0.0001 for all colonic segments). Adverse effects were more frequent in patients belonging to the CTE group (p<0.0028).

Conclusions: CTE allows an optimal distension of jejunal loops, but it is the most uncomfortable CT protocol. When performing CT-WE, an adequate retrograde distension of the terminal ileum was provided in a particularly high percentage of patients. CTe-WE provides a simultaneous optimal distension of both small and large bowel.

Publication types

  • Comparative Study
  • Evaluation Study

MeSH terms

  • Algorithms*
  • Barium Sulfate*
  • Contrast Media
  • Enema / methods*
  • Female
  • Humans
  • Intestines / diagnostic imaging*
  • Male
  • Middle Aged
  • Prospective Studies
  • Radiographic Image Enhancement / methods*
  • Radiographic Image Interpretation, Computer-Assisted / methods*
  • Reproducibility of Results
  • Sensitivity and Specificity
  • Tomography, X-Ray Computed / methods*

Substances

  • Contrast Media
  • Barium Sulfate