Removal of COD, phenols and ammonium from Lurgi coal gasification wastewater using A2O-MBR system

J Hazard Mater. 2012 Oct 15:235-236:78-84. doi: 10.1016/j.jhazmat.2012.07.012. Epub 2012 Jul 10.

Abstract

As a typical industrial wastewater, coal gasification wastewater has poor biodegradability and high toxicity. In this paper, a laboratory-scale anaerobic-anoxic-oxic membrane reactor (A(2)O-MBR) system was developed to investigate the treatment ability of coal gasification wastewater. The removal capacity of each pollutants used in this system were determined at different hydraulic residence times (HRT) and mixed liquor recycle ratios (R). The experimental results showed that this system could effectively deal with COD and phenol removal and remain in a stable level when the operational parameters altered, while the nitrification was sensitive to operational conditions. The best performance was obtained at HRT of 48 h and R of 3. The maximum removal efficiencies of COD, NH(4)(+)-N and phenols were 97.4%, 92.8% and 99.7%, with final concentrations in the effluent of 71 mg/L, 9.6 mg/L and 3 mg/L, respectively. Organics degradation and transformation were analyzed by GC/MS and it was found that anaerobic process played an important role in degradation of refractory compounds.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Anaerobiosis
  • Biological Oxygen Demand Analysis
  • Bioreactors*
  • Coal
  • Industrial Waste
  • Phenols / metabolism*
  • Quaternary Ammonium Compounds / metabolism*
  • Waste Disposal, Fluid / methods*
  • Wastewater
  • Water Pollutants, Chemical / metabolism*
  • Water Purification / methods

Substances

  • Coal
  • Industrial Waste
  • Phenols
  • Quaternary Ammonium Compounds
  • Waste Water
  • Water Pollutants, Chemical