Quantifying pulmonary regurgitation and right ventricular function in surgically repaired tetralogy of Fallot: a comparative analysis of echocardiography and magnetic resonance imaging

Circ Cardiovasc Imaging. 2012 Sep 1;5(5):637-43. doi: 10.1161/CIRCIMAGING.112.972588. Epub 2012 Aug 6.

Abstract

Background: Patients with repaired tetralogy of Fallot are monitored for pulmonary regurgitation (PR) and right ventricular (RV) function. We sought to compare measures of PR and RV function on echocardiogram to those on cardiac magnetic resonance (CMR) and to develop a new tool for assessing PR by echocardiogram.

Methods and results: Patients with repaired tetralogy of Fallot (n=143; 12.5±3.2 years) had an echocardiogram and CMR within 3 months of each other. On echocardiogram, RV function was assessed by (1) Doppler tissue imaging of the RV free wall and (2) myocardial performance index. The ratio of diastolic and systolic time-velocity integrals measured by Doppler of the main pulmonary artery was calculated. CMR variables included RV ejection fraction, RV volumes, and pulmonary regurgitant fraction (RF). Pulmonary regurgitation was graded as mild (RF<20%), moderate (RF=20-40%), and severe (RF>40%). On CMR, RF was 34+17% and RV ejection fraction was 61+8%. Echocardiography had good sensitivity identifying cases with RF>20% (sensitivity 97%; 95% CI: 92-99%) but overestimated the amount of PR when RF<20% (false-positive rate 36%; 95% CI: 18-57%). The diastolic and systolic time-velocity integrals on echocardiogram showed moderate correlation with RF on CMR (R=0.60; P<0.0001). On CMR, RF of 20% and 40% corresponded with a diastolic and systolic time-velocity integral of 0.49 (95% CI: 0.44-0.56) and 0.72 (95% CI: 0.68-0.76), respectively. RV myocardial performance index correlated modestly with RV ejection fraction (r=-0.33; P<0.001).

Conclusions: This study suggests that the diastolic and systolic time-velocity integrals ratio may make a modest contribution to the overall assessment of PR in patients with repaired tetralogy of Fallot and warrants further investigation. However, echocardiography continues to have a limited ability to quantify PR and RV function as compared with CMR.

Publication types

  • Comparative Study
  • Research Support, N.I.H., Extramural

MeSH terms

  • Adolescent
  • Cardiac Surgical Procedures / adverse effects*
  • Child
  • Cross-Sectional Studies
  • Diastole
  • Echocardiography, Doppler*
  • Female
  • Humans
  • Magnetic Resonance Imaging*
  • Male
  • Philadelphia
  • Predictive Value of Tests
  • Pulmonary Valve Insufficiency / diagnosis*
  • Pulmonary Valve Insufficiency / diagnostic imaging
  • Pulmonary Valve Insufficiency / etiology
  • Pulmonary Valve Insufficiency / physiopathology
  • Severity of Illness Index
  • Stroke Volume
  • Systole
  • Tetralogy of Fallot / complications
  • Tetralogy of Fallot / surgery*
  • Time Factors
  • Ventricular Dysfunction, Right / diagnosis*
  • Ventricular Dysfunction, Right / diagnostic imaging
  • Ventricular Dysfunction, Right / etiology
  • Ventricular Dysfunction, Right / physiopathology
  • Ventricular Function, Right*