Diagnostic accuracy of quantitative EUS elastography for discriminating malignant from benign solid pancreatic masses: a prospective, single-center study

Gastrointest Endosc. 2012 Nov;76(5):953-61. doi: 10.1016/j.gie.2012.05.034. Epub 2012 Jul 31.

Abstract

Background: Recent data suggest that quantitative EUS elastography, a novel technique that allows real-time quantification of tissue stiffness, can accurately differentiate malignant from benign solid pancreatic masses.

Objective: To externally validate the diagnostic utility of this technique in an independent cohort.

Design and setting: Prospective, single-center study. PATIENTS, INTERVENTIONS, AND METHODS: A total of 104 patients with evidence of a solid pancreatic mass on cross-sectional imaging and/or endosonography underwent 111 quantitative EUS elastography procedures. Multiple elastographic measurements of the mass lesion and soft-tissue reference areas were undertaken, and the corresponding strain ratios (SRs) were calculated. The final diagnosis was based on pancreatic cytology or histology.

Main outcome measurements: The area under the receiver-operating characteristic curve, sensitivity, specificity, positive predictive value, negative predictive value, and overall accuracy of quantitative EUS elastography for discriminating malignant from benign pancreatic masses.

Results: The final diagnoses were primary pancreatic carcinoma (71.2%), neuroendocrine tumor (10.6%), metastatic cancer (1.9%), and pancreatitis (16.3%). Malignant masses had a higher SR (P = .01) and lower mass elasticity (P = .003) than inflammatory ones. The areas under the receiver-operating characteristic curve for the detection of pancreatic malignancy of both SR and mass elasticity (0.69 and 0.72, respectively) were less favorable than reported recently. At the cut points providing the highest accuracy in this cohort (4.65 for SR and 0.27% for mass elasticity), quantitative EUS elastography had a sensitivity of 100.0% and 95.7%, specificity of 16.7% and 22.2%, positive predictive value of 86.1% and 86.4%, negative predictive value of 100.0% and 50.0%, and overall accuracy of 86.5% and 83.8%, respectively.

Limitations: Relatively small number of patients with benign disease.

Conclusion: In the largest single-center study to date, the diagnostic utility of quantitative EUS elastography for discriminating pancreatic masses was modest, suggesting that it may only supplement rather than supplant the role of pancreatic tissue sampling in the future.

Publication types

  • Clinical Trial

MeSH terms

  • Adult
  • Aged
  • Aged, 80 and over
  • Area Under Curve
  • Carcinoma / diagnostic imaging*
  • Carcinoma / pathology
  • Chi-Square Distribution
  • Elasticity Imaging Techniques*
  • Endosonography*
  • Female
  • Humans
  • Male
  • Middle Aged
  • Neuroendocrine Tumors / diagnostic imaging*
  • Neuroendocrine Tumors / pathology
  • Pancreatic Neoplasms / diagnostic imaging*
  • Pancreatic Neoplasms / pathology
  • Pancreatic Neoplasms / secondary
  • Pancreatitis / diagnostic imaging
  • Pancreatitis / pathology
  • Predictive Value of Tests
  • ROC Curve
  • Statistics, Nonparametric