Comparison of light transmittance in different thicknesses of zirconia under various light curing units

J Adv Prosthodont. 2012 May;4(2):93-6. doi: 10.4047/jap.2012.4.2.93. Epub 2012 May 30.

Abstract

Purpose: The objective of this study was to compare the light transmittance of zirconia in different thicknesses using various light curing units.

Materials and methods: A total of 21 disc-shaped zirconia specimens (5 mm in diameter) in different thicknesses (0.3, 0.5 and 0.8 mm) were prepared. The light transmittance of the specimens under three different light-curing units (quartz tungsten halogen, light-emitting diodes and plasma arc) was compared by using a hand-held radiometer. Statistical significance was determined using two-way ANOVA (α=.05).

Results: ANOVA revealed that thickness of zirconia and light curing unit had significant effects on light transmittance (P<.001).

Conclusion: Greater thickness of zirconia results in lower light transmittance. Light-emitting diodes light-curing units might be considered as effective as Plasma arc light-curing units or more effective than Quartz-tungsten-halogen light-curing units for polymerization of the resin-based materials.

Keywords: Light curing unit; Light transmittance; Zirconia.