Background: To date, no study has presented results of photodynamic diagnosis (PDD) cystoscopy compared with white-light cystoscopy (WLC) in daily practice. The aim of the present study is to evaluate the diagnostic accuracy of hexylaminolevulinate hydrochloride (Hexvix(®)) PDD cystoscopy compared with standard WLC used in daily practice.
Methods: An observational, open-label, comparative, controlled (within patient), multicenter study was carried out on 96 consecutive patients with suspected or confirmed bladder cancer. All patients had standard WLC followed by blue-light cystoscopy (BLC). Positive lesions detected using WLC and BLC were recorded. Biopsies/resection of each positive lesion were taken after the bladder was inspected. Sensitivity, specificity, positive predictive value, and negative predictive value with each method were calculated.
Results: Overall, 234 suspicious lesions were detected; 108 (46.2%) were histologically confirmed to be bladder tumors/carcinoma in situ (CIS). The sensitivity of BLC biopsies was significantly higher than for WLC technique (99.1 vs 76.8%; p < 0.00001). The relative sensitivity of BLC versus WLC was 1.289, showing superiority of BLC of 28.9%. The specificity of BLC biopsies was not significantly different compared with WLC (36.5 vs 30.2%). Positive predictive value for BLC- and WLC-guided biopsies was 54.9 and 50.9%, respectively. Negative predictive value per biopsy for BLC- and WLC-guided biopsies was 97.4 and 64.8%, respectively. BLC and WLC reached the correct diagnosis in 97.9 and 88.5% of patients, respectively. This difference was statistically significant (p = 0.0265). The lack of a random biopsy protocol was the major limitation of the study.
Conclusions: Hexvix(®) PDD cystoscopy used in daily practice enhances the diagnostic accuracy of standard cystoscopy with higher negative predictive value, potentially permitting an improvement in patient prognosis.