Fatal delayed coronary artery perforation after coronary stent implantation

Korean Circ J. 2012 May;42(5):352-4. doi: 10.4070/kcj.2012.42.5.352. Epub 2012 May 24.

Abstract

Most type I and II perforations are predominately caused by hydrophilic and stiff wires, often presented in the delayed form, and do not require pericardial drainage or surgical interventions. However, we report a type III delayed coronary artery perforation at the site of stent implantation after intervention without any evidence of immediate perforations. To the best of our knowledge, this is the first case report of angiographic documentation and treatment of delayed coronary perforation at the site of stent, presented as a cardiac arrest.

Keywords: Cardiac tamponade; Complications; Drug-eluting stent; Percutaneous transluminal coronary angioplasty.