Aortic banding and endovascular aneurysm repair in a case of juxtarenal aortic aneurysm with unsuitable infrarenal neck

J Vasc Surg. 2012 Jul;56(1):208-11. doi: 10.1016/j.jvs.2012.01.013. Epub 2012 Apr 10.

Abstract

The proximal aortic neck is one of the limiting factors for endovascular aneurysm repair (EVAR) and represents a crucial factor for success or failure of the procedure. In contrast to open surgery, where a clamp can be placed suprarenally but the repair performed infrarenally, EVAR requires a good infrarenal neck for durable fixation and seal. In a high-risk surgical 79-year-old patient with juxtarenal aortic aneurysm with unsuitable infrarenal neck, a hybrid procedure was chosen: juxtarenal aortic banding and EVAR. The banding allowed a successful EVAR by reshaping the juxtarenal aneurysmal aortic segment, hence converting a previously untreatable anatomy into a treatable one.

Publication types

  • Case Reports

MeSH terms

  • Aged
  • Angiography
  • Aortic Aneurysm, Abdominal / diagnostic imaging
  • Aortic Aneurysm, Abdominal / surgery*
  • Comorbidity
  • Endovascular Procedures / methods*
  • Humans
  • Male
  • Renal Artery
  • Tomography, X-Ray Computed
  • Ultrasonography