Determination of infarct size in ex vivo swine hearts by multidetector computed tomography using gadolinium as contrast medium

Invest Radiol. 2012 May;47(5):277-83. doi: 10.1097/RLI.0b013e31823fabc6.

Abstract

Objective: To demonstrate the feasibility of using multidetector computed tomography with gadolinium contrast (Gd-MDCT) for the quantification of myocardial infarct (MI).

Materials and methods: MI was induced in male swine (n = 6). One week later, the animals received 0.2-mmol/kg gadopentetate dimeglumine and were sacrificed. On the excised hearts, Gd-MDCT with several tube voltages (80, 120, and 140 kV), late gadolinium enhancement MRI (LGE-MRI), and triphenyl-tetrazolium-chloride staining were then conducted. We used a 2-SD threshold for the CT images and several threshold limits (2, 3, 4, 5, 6 SD, and full width at half-maximum [FWHM]) for the LGE-MRI images to delineate the infarct area. Total infarct volume and infarct fraction of each heart were calculated.

Results: MI size measured by MDCT at 140 kV showed good correlation with the reference triphenyl-tetrazolium-chloride value. Applying an 80-kV tube voltage, however, significantly underestimated MI size. In our study, the LGE-MRI method, using the 6-SD threshold, provided the most accurate determination of MI size. LGE-MRI, using the 2- and 3-SD threshold limits, significantly overestimated infarct size.

Conclusions: The Gd-MDCT technique has been found suitable for the evaluation of MI in an ex vivo experimental setting. Gd-MDCT has the ability to detect MI even at low kV settings, but accuracy is limited by a high image noise because of reduced photon flux.

Publication types

  • Research Support, N.I.H., Extramural

MeSH terms

  • Algorithms*
  • Animals
  • Contrast Media
  • Feasibility Studies
  • Gadolinium DTPA*
  • Image Enhancement / methods
  • Image Interpretation, Computer-Assisted / methods*
  • Imaging, Three-Dimensional / methods*
  • In Vitro Techniques
  • Male
  • Myocardial Infarction / diagnostic imaging*
  • Reproducibility of Results
  • Sensitivity and Specificity
  • Swine
  • Tomography, X-Ray Computed / methods*