Radiation emission from patients treated with selective hepatic radioembolization using yttrium-90 microspheres: are contact restrictions necessary?

J Vasc Interv Radiol. 2012 May;23(5):661-7. doi: 10.1016/j.jvir.2012.01.070. Epub 2012 Mar 21.

Abstract

Purpose: To estimate the possible radiation dose to other individuals from patients treated with yttrium-90 ((90)Y).

Materials and methods: Dosimetry data were analyzed after 143 consecutive administrations of (90)Y (124 resin, 19 glass) in 86 patients. External radiation exposure levels from patients were measured immediately after infusion. Total effective dose equivalent (TEDE) to maximally exposed individuals was calculated based on total body residence time and measured dose rate. These values were compared to Nuclear Regulatory Commission (NRC) regulations (maximum, 1 mSv) and other potential guidelines for caregivers, extensive caregivers, or pregnant contacts.

Results: Mean administered activity for resin microspheres was 0.71 GBq ± 0.35 (range, 0.07-1.6GBq). Mean TEDE dose to the maximally exposed contact was 0.03 mSv (range, 0.0005-0.16 mSv). For glass microspheres, mean administered activity was 2.8 GBq ± 1.5 (range, 0.37-5.14 GBq). Mean TEDE dose to the maximally exposed contact was 0.06 mSv (range, 0.0023-0.23 mSv). All (90)Y treatments were within current NRC regulations for release without instructions. One, three, and one infusion were beyond potential thresholds for caregivers, extensive caregivers, or pregnant contacts, respectively. For any contact scenario, release without instruction was appropriate when administered activity was less than 3 GBq.

Conclusions: All patients treated with (90)Y hepatic radioembolization to a maximum administered activity of 5.14 GBq and maximum dose rate of 10 uSv/h were releasable without contact restrictions according to the NRC contact scenario. Patients who receive more than 3 GBq during infusion may require dose rate measurement if more restrictive contact scenarios are considered.

Publication types

  • Video-Audio Media

MeSH terms

  • Caregivers
  • Embolization, Therapeutic / adverse effects
  • Embolization, Therapeutic / methods*
  • Female
  • Hepatic Artery
  • Humans
  • Liver Neoplasms / blood supply
  • Liver Neoplasms / pathology
  • Liver Neoplasms / radiotherapy*
  • Liver Neoplasms / secondary
  • Male
  • Microspheres
  • Patient Discharge
  • Philadelphia
  • Pregnancy
  • Pregnancy Complications / etiology
  • Pregnancy Complications / prevention & control
  • Radiation Dosage*
  • Radiation Injuries / etiology
  • Radiation Injuries / prevention & control
  • Radiation Monitoring
  • Radiopharmaceuticals / administration & dosage*
  • Radiopharmaceuticals / adverse effects
  • Radiotherapy Dosage
  • Risk Assessment
  • Risk Factors
  • Time Factors
  • Treatment Outcome
  • Yttrium Radioisotopes / administration & dosage*
  • Yttrium Radioisotopes / adverse effects

Substances

  • Radiopharmaceuticals
  • Yttrium Radioisotopes