Canal shaping with WaveOne Primary reciprocating files and ProTaper system: a comparative study

J Endod. 2012 Apr;38(4):505-9. doi: 10.1016/j.joen.2011.12.040. Epub 2012 Jan 31.

Abstract

Introduction: This study compared the canal curvature and axis modification after instrumentation with WaveOne Primary reciprocating files (Dentsply Maillefer, Ballaigues, Switzerland) and nickel-titanium (NiTi) rotary ProTaper (Dentsply Maillefer).

Methods: Thirty ISO 15, 0.02 taper, Endo Training Blocks (Dentsply Maillefer) were used. In all specimens, the glide path was achieved with PathFile 1, 2, and 3 (Dentsply Maillefer) at the working length (WL). Specimens were then assigned to 1 of 2 groups for shaping: specimens in group 1 were shaped with ProTaper S1-S2-F1-F2 at the WL and specimens in group 2 were shaped with WaveOne Primary reciprocating files at the WL. Pre- and postinstrumentation digital images were superimposed and processed with Matlab r2010b (The MathWorks Inc, Natick, MA) software to analyze the curvature-radius ratio (CRr) and the relative axis error (rAe), representing canal curvature modification. Data were analyzed with one-way balanced analyses of variance at 2 levels (P < .05).

Results: The instrument factor was extremely significant for both the CRr parameter (F(1) = 9.59, P = .004) and the rAe parameter (F(1) = 13.55, P = .001).

Conclusions: Canal modifications are reduced when the new WaveOne NiTi single-file system is used.

Publication types

  • Comparative Study
  • Randomized Controlled Trial

MeSH terms

  • Dental Alloys / chemistry
  • Dental Pulp Cavity / anatomy & histology*
  • Equipment Design
  • Humans
  • Image Processing, Computer-Assisted
  • Materials Testing
  • Models, Anatomic
  • Nickel / chemistry
  • Photography
  • Root Canal Preparation / instrumentation*
  • Root Canal Preparation / standards
  • Stress, Mechanical
  • Surface Properties
  • Titanium / chemistry

Substances

  • Dental Alloys
  • titanium nickelide
  • Nickel
  • Titanium