Short-Term and Two-Year Rate of Recurrent Cerebrovascular Events in Patients with Acute Cerebral Ischemia of Undetermined Aetiology, with and without a Patent Foramen Ovale

ISRN Neurol. 2011:2011:959483. doi: 10.5402/2011/959483. Epub 2011 Dec 15.

Abstract

Purpose. We investigated stroke recurrence in patients with acute ischemic stroke of undetermined aetiology, with or without a patent foramen ovale (PFO). Methods. Consecutive stroke patients underwent to Transcranial Doppler and Transesophageal Echocardiography for PFO detection. Secondary stroke prevention was based on current guidelines. Results. PFO was detected in 57/129 (44%) patients. The rate of recurrent stroke did not significantly differ between patients with and without a PFO: 0.0% versus 1.4% (1 week), 1.7% versus 2.7% (1 month), and 3.5% versus 4.2% (3 months), respectively. The 2-year rates were 10.4% (5/48) in medically treated PFO and 8.3% (6/72) in PFO-negative patients (P = 0.65), with a relative risk of 1.25. No recurrent events occurred in 9 patients treated with percutaneous closure of PFO. Conclusion. PFO was not associated with increased rate of recurrent stroke. Age-related factors associated with stroke recurrence in cryptogenic stroke should be taken into account when patients older than 55 years are included in PFO studies.