Surface treatment by electric discharge machining of Ti-6Al-4V alloy for potential application in orthopaedics

J Mech Behav Biomed Mater. 2012 Mar:7:96-105. doi: 10.1016/j.jmbbm.2011.07.001. Epub 2011 Jul 18.

Abstract

This study investigated the properties of Ti-6Al-4V alloy after surface treatment by the electric discharge machining (EDM) process. The EDM process with high peak currents proved to induce surface macro-roughness and to cause chemical changes to the surface. Evaluations were made of the mechanical properties by means of tensile tests, and of surface roughness for different peak currents of the EDM process. The EDM process with peak current of 29 A was found to induce sufficient surface roughness, and to have a low adverse effect on tensile properties. The chemical changes were studied by scanning electron microscopy equipped with an energy dispersive X-ray analyser (EDX). The surface of the benchmark samples was obtained by plasma-spraying a titanium dioxide coating. An investigation of the biocompatibility of the surface-treated Ti-6Al-4V samples in cultures of human osteoblast-like MG 63 cells revealed that the samples modified by EDM provided better substrates for the adhesion, growth and viability of MG 63 cells than the TiO2 coated surface. Thus, EDM treatment can be considered as a promising surface modification to orthopaedic implants, in which good integration with the surrounding bone tissue is required.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Alloys / chemistry*
  • Biocompatible Materials / chemistry*
  • Bone and Bones
  • Coated Materials, Biocompatible / chemistry*
  • Humans
  • Materials Testing
  • Prostheses and Implants*
  • Surface Properties
  • Titanium / chemistry*

Substances

  • Alloys
  • Biocompatible Materials
  • Coated Materials, Biocompatible
  • titanium alloy (TiAl6V4)
  • Titanium