Progress towards intra-operative measurement of femoral antetorsion

Technol Health Care. 2012;20(1):57-63. doi: 10.3233/THC-2011-0651.

Abstract

Rotational malalignment following intramedullary nailing is a well-recognised problem. The threshold for clinically relevant malrotation has been established to be in the region of 15° whereas the incidence of significant malrotation following femoral nailing ranges from 22 to 43 percent. Many studies have been performed to address this issue with the major challenge acknowledged to be intraoperative control of femoral anteversion. In the current study, the investigators developed and analysed a novel method to estimate the femoral antetorsion based on computed tomography (CT) data. They hypothesized that this method would be intra-operatively feasible and repeatable without further radiation. CT scans (n=166) of femoral neck fractures performed between 2005 and 2010 were evaluated. Twenty patients had a femoral neck fracture and thus were excluded. Every femoral neck was measured according the method described by Jend et al. and the current authors. In contrast to the Jend method, the current authors described femoral antetorsion as the angle between the ventral cortex of the femoral neck and the posterior condylar line. To determine this angle, the axial cuts from computed tomography data were studied. In order to maximise measurement consistencty among cases, the axial cut which displayed the intertrochanteric crest was selected. Mean femoral antetorsion is 12.15°±10.04° according to Jend et al. In comparison, a mean angle of 12.61°±11.16° was demonstrated in the current study. The absolute difference in measuring the femoral neck angle when these different methods are compared was 4.44°. Statistically, there is no significant difference between the mean results for femoral antetorsion. The advantage of the method proposed in the current study, is the opportunity to enter the ventral femoral cortex during the surgical procedure without disturbing the process of femoral nailing. Thus, the surgeon can avail of continuous control of femoral rotation intra-operatively.

MeSH terms

  • Bone Anteversion / etiology
  • Bone Anteversion / prevention & control*
  • Femoral Fractures / diagnostic imaging
  • Femoral Fractures / physiopathology
  • Femoral Fractures / surgery*
  • Femur / diagnostic imaging
  • Femur / physiopathology
  • Femur / surgery*
  • Fracture Fixation, Intramedullary / adverse effects
  • Fracture Fixation, Intramedullary / methods*
  • Humans
  • Postoperative Complications
  • Tomography, X-Ray Computed