A multidetector tomography protocol for follow-up of endovascular aortic aneurysm repair

Clinics (Sao Paulo). 2011;66(12):2025-9. doi: 10.1590/s1807-59322011001200005.

Abstract

Objective: The purpose of this study was to improve the use of 64-channel multidetector computed tomography using lower doses of ionizing radiation during follow-up procedures in a series of patients with endovascular aortic aneurysm repair.

Methods: Thirty patients receiving 5 to 29 months of follow-up after endovascular aortic aneurysm repair were analyzed using a 64-channel multidetector computed tomography device by an exam that included pre-and postcontrast with both arterial and venous phases. Leak presence and type were classified based on the exam phase.

Results: Endoleaks were identified in 8/30 of cases; the endoleaks in 3/8 of these cases were not visible in the arterial phases of the exams.

Conclusion: The authors conclude that multidetector computed tomography with pre-contrast and venous phases should be a part of the ongoing follow-up of patients undergoing endovascular aortic aneurysm repair. The arterial phase can be excluded when the aneurism is stable or regresses. These findings permit a lower radiation dose without jeopardizing the correct diagnosis of an endoleak.

MeSH terms

  • Aged
  • Aged, 80 and over
  • Aortic Aneurysm / diagnostic imaging*
  • Aortic Aneurysm / surgery*
  • Contrast Media
  • Female
  • Follow-Up Studies
  • Humans
  • Male
  • Middle Aged
  • Multidetector Computed Tomography*
  • Radiation Dosage
  • Stents

Substances

  • Contrast Media