Effect of phosphate-based glass fibre surface properties on thermally produced poly(lactic acid) matrix composites

J Mater Sci Mater Med. 2011 Dec;22(12):2659-72. doi: 10.1007/s10856-011-4453-x. Epub 2011 Oct 16.

Abstract

Incorporation of soluble bioactive glass fibres into biodegradable polymers is an interesting approach for bone repair and regeneration. However, the glass composition and its surface properties significantly affect the nature of the fibre-matrix interface and composite properties. Herein, the effect of Si and Fe on the surface properties of calcium containing phosphate based glasses (PGs) in the system (50P(2)O(5)-40CaO-(10-x)SiO(2)-xFe(2)O(3), where x = 0, 5 and 10 mol.%) were investigated. Contact angle measurements revealed a higher surface energy, and surface polarity as well as increased hydrophilicity for Si doped PG which may account for the presence of surface hydroxyl groups. Two PG formulations, 50P(2)O(5)-40CaO-10Fe(2)O(3) (Fe10) and 50P(2)O(5)-40CaO-5Fe(2)O(3)-5SiO(2) (Fe5Si5), were melt drawn into fibres and randomly incorporated into poly(lactic acid) (PLA) produced by melt processing. The ageing in deionised water (DW), mechanical property changes in phosphate buffered saline (PBS) and cytocompatibility properties of these composites were investigated. In contrast to Fe10 and as a consequence of the higher surface energy and polarity of Fe5Si5, its incorporation into PLA led to increased inorganic/organic interaction indicated by a reduction in the carbonyl group of the matrix. PLA chain scission was confirmed by a greater reduction in its molecular weight in PLA-Fe5Si5 composites. In DW, the dissolution rate of PLA-Fe5Si5 was significantly higher than that of PLA-Fe10. Dissolution of the glass fibres resulted in the formation of channels within the matrix. Initial flexural strength was significantly increased through PGF incorporation. After PBS ageing, the reduction in mechanical properties was greater for PLA-Fe5Si5 compared to PLA-Fe10. MC3T3-E1 preosteoblasts seeded onto PG discs, PLA and PLA-PGF composites were evaluated for up to 7 days indicating that the materials were generally cytocompatible. In addition, cell alignment along the PGF orientation was observed showing cell preference towards PGF.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • 3T3 Cells
  • Absorbable Implants
  • Animals
  • Biocompatible Materials / chemistry*
  • Calcium / chemistry
  • Calcium Phosphates / chemistry
  • Glass / chemistry*
  • Hot Temperature
  • Ions
  • Lactic Acid / chemistry*
  • Materials Testing
  • Mice
  • Phosphates / chemistry*
  • Polyesters
  • Polymers / chemistry*
  • Stress, Mechanical
  • Surface Properties
  • Wettability
  • X-Ray Diffraction

Substances

  • Biocompatible Materials
  • Calcium Phosphates
  • Ions
  • Phosphates
  • Polyesters
  • Polymers
  • fiberglass
  • Lactic Acid
  • poly(lactide)
  • calcium phosphate
  • Calcium