Improvements to standard methodologies for the analytical determination of metals in stationary-source emissions samples

J Air Waste Manag Assoc. 2011 Jul;61(7):764-70. doi: 10.3155/1047-3289.61.7.764.

Abstract

Deficiencies with the current European reference method for the analysis using inductively couple plasma-mass spectrometry of metals in samples from stationary emissions sources are presented based on experimental data obtained from real samples. The effect of these deficiencies on the quality and accuracy of data is highlighted with biases of up to 40% being observed in real samples. Suggestions to improve the performance of the standard method are presented. In particular, the beneficial effect of using a drift correction procedure to account for the decrease in instrument sensitivity observed during an analytical measurement series is demonstrated. It is shown that this corrective procedure results in substantial improvements to the accuracy of data produced.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Air Pollutants / chemistry*
  • England
  • Environmental Monitoring / instrumentation
  • Environmental Monitoring / methods*
  • Metals / chemistry*
  • Quality Control
  • Time Factors

Substances

  • Air Pollutants
  • Metals