A dangerous entanglement

Hemodial Int. 2011 Jul;15(3):424-6. doi: 10.1111/j.1542-4758.2011.00567.x. Epub 2011 Jun 23.

Abstract

Entrapment of guidewires by inferior vena cava filters can occur during the blind insertion of a jugular or a subclavian central venous catheter. Recently, few case reports have been published in the radiology literature. In addition, others have described endovascular techniques aimed at removing entrapped guidewires, avoiding the possibility of vena cava rupture. Given that a temporary hemodialysis venous catheter is frequently used as a first access, the possibility of entrapping the dialysis catheter guidewire should not be neglected.

Publication types

  • Case Reports
  • Review

MeSH terms

  • Aged
  • Catheterization / adverse effects*
  • Catheters*
  • Foreign Bodies / etiology*
  • Foreign Bodies / therapy*
  • Humans
  • Male
  • Renal Dialysis / adverse effects*
  • Vena Cava Filters*
  • Vena Cava, Inferior