Concomitant off-pump modified maze and coronary surgery

Ann Thorac Surg. 2011 Jun;91(6):e96-8. doi: 10.1016/j.athoracsur.2011.01.094.

Abstract

We describe a modification of the Cox-Maze III using bipolar radiofrequency combined with off-pump coronary artery surgery for the treatment of patients with coronary artery disease and long-standing permanent atrial fibrillation. This study reports the midterm outcome of 12 patients with coronary artery disease and long-standing permanent atrial fibrillation who underwent off-pump coronary artery surgery and concomitant modified Maze with bipolar radiofrequency. At a mean follow-up of 23 months, all patients were alive, and 75% (9 of 12) had sinus rhythm. Our modified Maze can be safely and effectively combined with coronary artery surgery in an off-pump setting.

MeSH terms

  • Aged
  • Animals
  • Atrial Fibrillation / surgery*
  • Catheter Ablation / methods*
  • Coronary Artery Bypass, Off-Pump / methods*
  • Coronary Artery Disease / surgery*
  • Humans
  • Middle Aged
  • Swine