Abstract

A simple analytical method was developed for the determination of chlorfenapyr residues in leeks grown under greenhouse conditions. Residues were extracted by salting out, analyzed by gas chromatography with microelectron-capture detection, and confirmed via gas chromatography-mass spectrometry. The calibration curves were found to be linear with correlation coefficients (r(2) ) in excess of 0.998. The limits of detection and quantification were 0.0015 and 0.005 mg kg(-1) , respectively. For validation purposes, recovery studies were carried out at low and high levels. Yield recovery rates were 87.27-89.64% with a relative standard deviation <6%. A maximum of 0.32 mg kg(-1) of chlorfenapyr residue was detected in leek sample sprayed three times at 7 day intervals until 7 days prior to harvest. The results of this study suggest that chlorfenapyr is acceptable for application in/on leeks under the recommended dosage regimen.

MeSH terms

  • Agriculture
  • Chromatography, Gas / methods*
  • Gas Chromatography-Mass Spectrometry
  • Limit of Detection
  • Linear Models
  • Onions / chemistry*
  • Pesticide Residues / analysis*
  • Pyrethrins / analysis*
  • Reproducibility of Results

Substances

  • Pesticide Residues
  • Pyrethrins
  • chlorfenapyr