Usefulness of Real-Time 4D Ultrasonography during Radiofrequency Ablation in a Case of Hepatocellular Carcinoma

Case Rep Gastroenterol. 2011 Feb 1;5(1):82-7. doi: 10.1159/000321721.

Abstract

We report a case of hepatocellular carcinoma (HCC) with chronic hepatitis C virus infection successfully treated with percutaneous radiofrequency ablation (RFA) under live four-dimensional (4D) echo guidance. A 65-year-old Japanese man had a HCC nodule in the liver S5 region 2.0 cm in diameter. We performed real-time 4D ultrasonography during RFA therapy with a LeVeen needle electrode. The echo guidance facilitated an accurate approach for the needle puncture. The guidance was also useful for confirming whether an adequate safety margin for the nodule had been obtained. Thus real-time 4D ultrasonography echo technique appears to provide safe guidance of RFA needles via accurate targeting of HCC nodules, thereby allowing real-time visualization when combined with echo contrast. Furthermore the position of the needle in a still image was confirmed in every area using a multiview procedure.

Keywords: Hepatocellular carcinoma; Radiofrequency ablation; Real-time 4D ultrasonography.

Publication types

  • Case Reports