High fire resistance in blocks containing coal combustion fly ashes and bottom ash

Waste Manag. 2011 Aug;31(8):1783-9. doi: 10.1016/j.wasman.2011.03.017. Epub 2011 Apr 20.

Abstract

Fire resistance recycled blocks, containing fly ash and bottom ash from coal combustion power plants with a high fire resistance, are studied in this paper by testing different compositions using Portland cement type II, sand, coarse aggregate and fly ash (up to 50% of total weight) and bottom ash (up to 30% of total weight). The fire resistance, physical-chemical (density, pH, humidity, and water absorption capacity), mechanical (compressive and flexural strength), and leaching properties are measured on blocks made with different proportions of fly ash and bottom ash. The standard fire resistance test is reproduced on 28cm-high, 18cm-wide and 3cm-thick units, and is measured as the time needed to reach a temperature of 180°C on the non-exposed surface of the blocks for the different compositions. The results show that the replacement of fine aggregate with fly ash and of coarse aggregate with bottom ash have a remarkable influence on fire resistance and cause no detriment to the mechanical properties of the product. Additionally, according to the leaching tests, no environmental problems have been detected in the product. These results lead to an analysis of the recycling possibilities of these by-products in useful construction applications for the passive protection against fire.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Coal Ash / chemistry*
  • Coal*
  • Construction Materials*
  • Fires / prevention & control*
  • Recycling / methods*

Substances

  • Coal
  • Coal Ash