Alcohol and metal determination in alcoholic beverages through high-temperature liquid-chromatography coupled to an inductively coupled plasma atomic emission spectrometer

J Chromatogr A. 2011 Jun 3;1218(22):3439-46. doi: 10.1016/j.chroma.2011.03.060. Epub 2011 Apr 1.

Abstract

In the present work, an inductively coupled plasma atomic emission spectrometry (ICP-AES) system was used as a high temperature liquid chromatography (HTLC) detector for the determination of alcohols and metals in beverages. For the sake of comparison, a refractive index (RI) detector was also employed for the first time to detect alcohols with HTLC. The organic compounds studied were methanol, ethanol, propan-1-ol and butan-1-ol (in the 10-125 mg/L concentration range) and the elements tested were magnesium, aluminum, copper, manganese and barium at concentrations included between roughly 0.01 and 80 mg/L. Column heating temperatures ranged from 80 to 175 °C and the optimum ones in terms of peak resolution, sensitivity and column lifetime were 125 and 100 °C for the HTLC-RI and HTLC-ICP-AES couplings, respectively. The HTLC-ICP-AES interface design (i.e., spray chamber design and nebulizer type used) was studied and it was found that a single pass spray chamber provided about 2 times higher sensitivities than a cyclonic conventional design. Comparatively speaking, limits of detection for alcohols were of the same order for the two evaluated detection systems (from 5 to 25 mg/L). In contrast, unlike RI, ICP-AES provided information about the content of both organic and inorganic species. Furthermore, temperature programming was applied to shorten the analysis time and it was verified that ICP-AES was less sensitive to temperature changes and modifications in the analyte chemical nature than the RI detector. Both detectors were successfully applied to the determination of short chain alcohols in several beverages such as muscatel, pacharan, punch, vermouth and two different brands of whiskeys (from 10 to 40 g of ethanol/100 g of sample). The results of the inorganic elements studied by HTLC-ICP-AES were compared with those obtained using inductively coupled plasma mass spectrometry (ICP-MS) obtaining good agreement between them. Recoveries found for spiked samples were close to 100% for both, inorganic elements (with both HLTC-ICP-AES and ICP-MS) and alcohols (with both HTLC-ICP-AES and HTLC-RI hyphenations).

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Alcoholic Beverages / analysis*
  • Alcohols / analysis*
  • Alcohols / isolation & purification
  • Chromatography, Liquid / methods*
  • Hot Temperature
  • Mass Spectrometry / methods*
  • Metals, Heavy / analysis*
  • Metals, Heavy / isolation & purification
  • Sensitivity and Specificity

Substances

  • Alcohols
  • Metals, Heavy